Fieldbus, decentr. periphery - digital I/O module Schneider TeSys island
Add to selection
General information
Ordercode YESSS
7253-5441 
Product code
TPRDG4X2 
EAN code
3606489832896
Product group
Fieldbus, decentr. periphery - digital I/O module
Brand
Schneider
Serie
TeSys island
Type
TPRDG4X2
Ein- Ausgangskarte digital, TeSys island Karte 4 Eingänge, 2
Ein- Ausgangskarte digital, TeSys island Karte 4 Eingänge, 2 Ausgänge
Product description
TeSys island - Lastmanagementsystem bis 80A. Digitale Eingangs- und Ausgangskarte. Anschluss Push-in, Steuerspannung 24V DC, Status LED, 4 digitale Eingänge und 2 Ausgänge. Gerätebreite 22,5 mm, für Hutschienenmontage. Digitale Eingangs- und Ausgangskarte zum Einsammeln und übergeben anwendungsspezifischer Signale. TeSys island - Industrie 4.0 optimiertes Lastmanagmentsystem mit IIOT Protokollen.
Product specifications
Digital outputs configurable
Yes
Digital inputs configurable
Yes
Number of digital outputs
2
Number of digital inputs
4
Supply voltage DC
20.4 - 28.8 V
Voltage type (supply voltage)
DC
Input current at signal 1
7 mA
Permitted voltage at input
0 - 28.8 V
Type of voltage (input voltage)
DC
Type of digital output
Other
Output current
0.5 A
Permitted voltage at output
0 - 28.8 V
Type of output voltage
DC
Short-circuit protection, outputs available
No
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
2
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
IO link master
No
System accessory
Yes
Radio standard GPRS
No
Degree of protection (IP)
IP20
Radio standard GSM
No
Type of electric connection
Plug-in connection
Mobile communications standard 3G (UMTS)
No
Time delay at signal change
5 - 5 ms
Fieldbus connection over separate bus coupler possible
Yes
Suitable for rail mounting
Yes
Wall mounting/direct mounting
No
Front built-in possible
No
SIL according to IEC 61508
None
Rack-assembly possible
No
Suitable for safety functions
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
25 mm
Height
118 mm
Depth
114 mm
Supporting protocol for EtherCAT
No
Product information