Measuring range selection
Automatic
Max. voltage measuring range AC
600 V
Lowest resolution, AC voltage
0.1 mV
Max. voltage measuring range DC
600 V
Lowest resolution, DC voltage
0.1 mV
Max. current measuring range, AC
10 A
Lowest resolution, AC current
1000 µA
Max. current measuring range, DC
10 A
Lowest resolution, DC current
0.1 µA
Milliohm measurement with 4 wire technique (Kelvin connection)
No
Lowest resolution, resistance
0.1 Ohm
Resistance test/diode test
Yes
Temperature measurement RTD
No
Capacitance measurement
Yes
Temperature measurement TC
No
Frequency measurement
Yes
Max. temperature measuring range
400 °C
With decibel measurement (dB)
No
Lowest resolution temperature
0.1 °C
Relative value measurement
Yes
Inductance measurement
No
Max. capacitance measuring range
1000 µF
With conductivity measurement
No
Lowest resolution, capacitance
0.00001 µF
Max. frequency measuring range
50 kHz
Lowest resolution, frequency
0.01 Hz
Duty cycle measurements
No
Nominal test voltage 10 V
No
Nominal test voltage 50 V
No
Measuring circuit category
CAT IV
Nominal test voltage 100 V
No
Nominal test voltage 250 V
No
Nominal test voltage 500 V
No
Nominal test voltage 1000 V
No
Cable length measurement
No
Cable symmetry testing for two wire connections a-b-E
No
Power and energy measurement
No
Harmonics analysis/power quality
No
Rotational speed measuring
No
Automatic circuit breaker
No
Max. voltage measuring circuit category
300 V
Explosion-tested version
No
Scaling bar graph linear
No
Scaling bar graph logarithmic
No
With display backlight
Yes
Temperature measurement
Yes
Degree of protection (IP)
IP30
Max. resistance measuring range
40 mOhm
Isolation resistance measuring range
0 - 0 mOhm
Max. voltage measuring range AC/DC
600 V
Lowest resolution, AC/DC voltage
0.1 mV
Max. current measuring range, AC/DC
10 A
Lowest resolution, AC/DC current
0.1 µA
Max. current measuring range with clip factor
0 A
Measurement principle
True root mean square
Relative measurement accuracy
0.5 %
High voltage test for motor windings
No
Calibration according to ISO/IEC 17025
No
Calibration certificate according to DAkkS
No